41 to
80 of
337 Items
- Solid State Interface Relays
Page 2 of 9
Brand |
: |
Phoenix Contact |
MFR # |
: |
2905215 |
Mounting Type |
: |
DIN Rail |
Contact Configuration |
: |
SPST |
Series |
: |
PLC-HPT |
Manufacturer Part No. |
: |
2905215 |
|
Brand |
: |
Omron |
MFR # |
: |
G3VM-61MT(TR01) |
Maximum Control Voltage |
: |
2.42 Vdc |
Maximum Load Current |
: |
550 mA |
Mounting Type |
: |
Surface Mount |
Maximum Load Voltage |
: |
100 V |
Switching Type |
: |
T-switch |
Manufacturer Part No. |
: |
G3VM-61MT(TR01) |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2905214 |
Maximum Control Voltage |
: |
28.8 V dc |
Maximum Load Current |
: |
100 mA |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
253 V ac |
Minimum Control Voltage |
: |
19.2 V dc |
Control Voltage Range |
: |
19.2 → 28.8 V dc |
Switching Type |
: |
AC/DC |
Contact Configuration |
: |
SPST |
Load Voltage Range |
: |
24 → 253V ac |
Minimum Load Voltage |
: |
24 V ac |
Terminal Type |
: |
Push In |
Series |
: |
PLC-HSC |
Output Device |
: |
PLC |
Range |
: |
PLC |
Maximum Turn On Time |
: |
30ms |
Manufacturer Part No. |
: |
2905214 |
|
Brand |
: |
Omron |
MFR # |
: |
G3VM-61MT(TR05) |
Maximum Control Voltage |
: |
2.42 Vdc |
Maximum Load Current |
: |
550 mA |
Mounting Type |
: |
Surface Mount |
Maximum Load Voltage |
: |
100 V |
Switching Type |
: |
T-switch |
Manufacturer Part No. |
: |
G3VM-61MT(TR05) |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900384 |
Maximum Load Current |
: |
1 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
60 V dc |
Minimum Load Voltage |
: |
48 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2900384 |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900385 |
Maximum Load Current |
: |
1 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
132 V dc |
Minimum Load Voltage |
: |
88 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2900385 |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900381 |
Maximum Load Current |
: |
1 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
6 V dc |
Minimum Load Voltage |
: |
4 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2900381 |
|
Brand |
: |
Omron |
MFR # |
: |
G3VM-101MT(TR01) |
Maximum Control Voltage |
: |
2.42 Vdc |
Maximum Load Current |
: |
800 mA |
Mounting Type |
: |
Surface Mount |
Maximum Load Voltage |
: |
60 V |
Switching Type |
: |
T-switch |
Manufacturer Part No. |
: |
G3VM-101MT(TR01) |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900382 |
Maximum Load Current |
: |
1 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
14.4 V dc |
Minimum Load Voltage |
: |
9.6 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2900382 |
|
Brand |
: |
Omron |
MFR # |
: |
G3VM-101MT(TR05) |
Maximum Control Voltage |
: |
2.42 Vdc |
Maximum Load Current |
: |
800 mA |
Mounting Type |
: |
Surface Mount |
Maximum Load Voltage |
: |
60 V |
Switching Type |
: |
T-switch |
Manufacturer Part No. |
: |
G3VM-101MT(TR05) |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2904632 |
Maximum Load Current |
: |
10 mA |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
28.8 V dc |
Minimum Load Voltage |
: |
19.2 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2904632 |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2904586 |
Maximum Load Current |
: |
100 mA |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
120 V dc |
Minimum Load Voltage |
: |
67.2 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2904586 |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2908174 |
Maximum Control Voltage |
: |
121 V dc, 132 V ac |
Maximum Load Current |
: |
3 mA |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
30 V dc |
Minimum Control Voltage |
: |
88 V dc, 96 V ac |
Control Voltage Range |
: |
96 → 132 V ac; 88 → 121 V dc |
Switching Type |
: |
AC/DC |
Contact Configuration |
: |
SPST |
Load Voltage Range |
: |
5 → 30V dc |
Minimum Load Voltage |
: |
5 V dc |
Terminal Type |
: |
Push In |
Series |
: |
PLC-OPT |
Output Device |
: |
PLC |
Range |
: |
PLC |
Maximum Turn On Time |
: |
6ms |
Manufacturer Part No. |
: |
2908174 |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-SR700-D DC12 |
Maximum Load Current |
: |
3 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
24 V dc |
Minimum Load Voltage |
: |
5 V dc |
Series |
: |
G3RV |
Output Device |
: |
MOSFET |
Manufacturer Part No. |
: |
G3RV-SR700-D DC12 |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900372 |
Maximum Control Voltage |
: |
132 V ac |
Maximum Load Current |
: |
10 mA |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
253 V ac |
Minimum Control Voltage |
: |
99 V dc, 108 V ac |
Control Voltage Range |
: |
108 → 132 V ac; 99 → 121 V dc |
Switching Type |
: |
AC/DC |
Contact Configuration |
: |
SPST |
Load Voltage Range |
: |
24 → 253V ac |
Minimum Load Voltage |
: |
24 V ac |
Terminal Type |
: |
Push In |
Series |
: |
PLC-OPT |
Output Device |
: |
PLC |
Range |
: |
PLC |
Maximum Turn On Time |
: |
10ms |
Manufacturer Part No. |
: |
2900372 |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST500-AL AC110 |
Maximum Control Voltage |
: |
110 V ac |
Maximum Load Current |
: |
2 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
264 V ac |
Minimum Control Voltage |
: |
88 V |
Control Voltage Range |
: |
88 - 121 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
75 - 264V |
Minimum Load Voltage |
: |
75 V ac |
Terminal Type |
: |
Push In |
Input Current |
: |
7.7mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
100 mA |
Length |
: |
88mm |
Output Device |
: |
Triac |
Depth |
: |
87.1mm |
Rise Time |
: |
3ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
3 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST500-AL AC110 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900359 |
Maximum Control Voltage |
: |
132 V dc |
Maximum Load Current |
: |
100 mA |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
48 V dc |
Minimum Control Voltage |
: |
99 V dc |
Control Voltage Range |
: |
99 → 132 V dc |
Switching Type |
: |
AC/DC |
Contact Configuration |
: |
SPST |
Load Voltage Range |
: |
3 → 48V dc |
Minimum Load Voltage |
: |
3 V dc |
Terminal Type |
: |
Push In |
Series |
: |
PLC-OPT |
Output Device |
: |
PLC |
Range |
: |
PLC |
Maximum Turn On Time |
: |
6ms |
Manufacturer Part No. |
: |
2900359 |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2908176 |
Maximum Control Voltage |
: |
242 V dc, 253 V ac |
Maximum Load Current |
: |
3 mA |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
253 V ac |
Minimum Control Voltage |
: |
176 V dc, 184 V ac |
Control Voltage Range |
: |
184 → 253 V ac; 176 → 242 V dc |
Switching Type |
: |
AC/DC |
Contact Configuration |
: |
SPST |
Load Voltage Range |
: |
5 → 30V dc |
Minimum Load Voltage |
: |
5 V dc |
Terminal Type |
: |
Push In |
Series |
: |
PLC-OPT |
Output Device |
: |
PLC |
Range |
: |
PLC |
Maximum Turn On Time |
: |
3ms |
Manufacturer Part No. |
: |
2908176 |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST700-A AC110 |
Maximum Control Voltage |
: |
110 V ac |
Maximum Load Current |
: |
2 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
264 V ac |
Minimum Control Voltage |
: |
88 V |
Control Voltage Range |
: |
88 - 121 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
75 - 264V |
Minimum Load Voltage |
: |
75 V ac |
Terminal Type |
: |
Screw |
Input Current |
: |
6.2mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
100 mA |
Length |
: |
88mm |
Output Device |
: |
Triac |
Depth |
: |
87.1mm |
Rise Time |
: |
11ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
11 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST700-A AC110 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900361 |
Maximum Load Current |
: |
3.5 mA |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
48 V dc |
Minimum Load Voltage |
: |
3 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2900361 |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST500-A AC110 |
Maximum Control Voltage |
: |
110 V ac |
Maximum Load Current |
: |
2 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
264 V ac |
Minimum Control Voltage |
: |
88 V |
Control Voltage Range |
: |
88 - 121 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
75 - 264V |
Minimum Load Voltage |
: |
75 V ac |
Terminal Type |
: |
Push In |
Input Current |
: |
6.2mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
100 mA |
Length |
: |
88mm |
Output Device |
: |
Triac |
Depth |
: |
87.1mm |
Rise Time |
: |
11ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
11 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST500-A AC110 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900365 |
Maximum Control Voltage |
: |
57.6 V dc |
Maximum Load Current |
: |
3 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
33 V dc |
Minimum Control Voltage |
: |
38.4 V dc |
Control Voltage Range |
: |
38.4 → 57.6 V dc |
Switching Type |
: |
DC |
Contact Configuration |
: |
SPST |
Load Voltage Range |
: |
3 → 33V dc |
Minimum Load Voltage |
: |
3 V dc |
Terminal Type |
: |
Push In |
Series |
: |
PLC-OPT |
Output Device |
: |
PLC |
Range |
: |
PLC |
Maximum Turn On Time |
: |
20 μs |
Manufacturer Part No. |
: |
2900365 |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST700-AL AC110 |
Maximum Control Voltage |
: |
110 V ac |
Maximum Load Current |
: |
2 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
264 V ac |
Minimum Control Voltage |
: |
88 V |
Control Voltage Range |
: |
88 - 121 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
75 - 264V |
Minimum Load Voltage |
: |
75 V ac |
Terminal Type |
: |
Screw |
Input Current |
: |
7.7mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
100 mA |
Length |
: |
88mm |
Output Device |
: |
Triac |
Depth |
: |
87.1mm |
Rise Time |
: |
3ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
3 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST700-AL AC110 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST700-D AC110 |
Maximum Control Voltage |
: |
110 V ac |
Maximum Load Current |
: |
3 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
26.4 Vdc |
Minimum Control Voltage |
: |
88 V |
Control Voltage Range |
: |
88 - 121 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
3 - 26.4V |
Minimum Load Voltage |
: |
3 Vdc |
Terminal Type |
: |
Screw |
Input Current |
: |
6.7mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
0.1 mA |
Length |
: |
88mm |
Output Device |
: |
Photovoltage Coupler |
Depth |
: |
87.1mm |
Rise Time |
: |
6ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
6 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST700-D AC110 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900389 |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
253 V dc |
Minimum Load Voltage |
: |
184 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2900389 |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900395 |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
120 V dc |
Minimum Load Voltage |
: |
67.2 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2900395 |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST500-D AC110 |
Maximum Control Voltage |
: |
110 V ac |
Maximum Load Current |
: |
3 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
26.4 Vdc |
Minimum Control Voltage |
: |
88 V |
Control Voltage Range |
: |
88 - 121 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
3 - 26.4V |
Minimum Load Voltage |
: |
3 Vdc |
Terminal Type |
: |
Push In |
Input Current |
: |
6.7mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
0.1 mA |
Length |
: |
88mm |
Output Device |
: |
MOSFET |
Depth |
: |
87.1mm |
Rise Time |
: |
6ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
6 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST500-D AC110 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST500-A DC12 |
Maximum Control Voltage |
: |
12 Vdc |
Maximum Load Current |
: |
2 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
264 V ac |
Minimum Control Voltage |
: |
10.8 V |
Control Voltage Range |
: |
9.6 - 13.2 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
75 - 264V |
Minimum Load Voltage |
: |
75 V ac |
Terminal Type |
: |
Push In |
Input Current |
: |
15mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
100 mA |
Length |
: |
88mm |
Output Device |
: |
Triac |
Depth |
: |
87.1mm |
Rise Time |
: |
11ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
11 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST500-A DC12 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900354 |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
60 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2900354 |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST700-AL DC12 |
Maximum Control Voltage |
: |
12 Vdc |
Maximum Load Current |
: |
2 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
264 V ac |
Minimum Control Voltage |
: |
10.8 V |
Control Voltage Range |
: |
9.6 - 13.2 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
75 - 264V |
Minimum Load Voltage |
: |
75 V ac |
Terminal Type |
: |
Screw |
Input Current |
: |
15mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
100 mA |
Length |
: |
88mm |
Output Device |
: |
Triac |
Depth |
: |
87.1mm |
Rise Time |
: |
3ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
3 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST700-AL DC12 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900390 |
Mounting Type |
: |
DIN Rail |
Minimum Load Voltage |
: |
100 V dc |
Series |
: |
PLC-OPT |
Range |
: |
PLC |
Manufacturer Part No. |
: |
2900390 |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900396 |
Mounting Type |
: |
DIN Rail |
Contact Configuration |
: |
SPST |
Terminal Type |
: |
Push In |
Input Current |
: |
5.5mA |
Height |
: |
86mm |
Series |
: |
PLC-OPT-110DC |
Length |
: |
80mm |
Depth |
: |
6.2mm |
Dimensions |
: |
80 x 6.2 x 86mm |
Minimum Operating Temperature |
: |
-25°C |
Maximum Operating Temperature |
: |
+70°C |
Manufacturer Part No. |
: |
2900396 |
Operating Temperature Range |
: |
-25 → +70°C |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST500-AL DC12 |
Maximum Control Voltage |
: |
12 Vdc |
Maximum Load Current |
: |
2 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
264 V ac |
Minimum Control Voltage |
: |
10.8 V |
Control Voltage Range |
: |
9.6 - 13.2 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
75 - 264V |
Minimum Load Voltage |
: |
75 V ac |
Terminal Type |
: |
Push In |
Input Current |
: |
15mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
100 mA |
Length |
: |
88mm |
Output Device |
: |
Triac |
Depth |
: |
87.1mm |
Rise Time |
: |
3ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
3 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST500-AL DC12 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST700-A DC12 |
Maximum Control Voltage |
: |
12 Vdc |
Maximum Load Current |
: |
2 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
264 V ac |
Minimum Control Voltage |
: |
10.8 V |
Control Voltage Range |
: |
9.6 - 13.2 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
75 - 264V |
Minimum Load Voltage |
: |
75 V ac |
Terminal Type |
: |
Screw |
Input Current |
: |
15mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
100 mA |
Length |
: |
88mm |
Output Device |
: |
Triac |
Depth |
: |
87.1mm |
Rise Time |
: |
11ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
11 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST700-A DC12 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900380 |
Mounting Type |
: |
DIN Rail |
Contact Configuration |
: |
SPST |
Terminal Type |
: |
Push In |
Input Current |
: |
3mA |
Height |
: |
86mm |
Series |
: |
PLC-OPT-110DC |
Length |
: |
80mm |
Depth |
: |
6.2mm |
Dimensions |
: |
80 x 6.2 x 86mm |
Minimum Operating Temperature |
: |
-25°C |
Maximum Operating Temperature |
: |
+70°C |
Manufacturer Part No. |
: |
2900380 |
Operating Temperature Range |
: |
-25 → +70°C |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900355 |
Mounting Type |
: |
DIN Rail |
Contact Configuration |
: |
SPST |
Terminal Type |
: |
Push In |
Input Current |
: |
3.5mA |
Height |
: |
94mm |
Series |
: |
PLC-OPT-120UC |
Length |
: |
80mm |
Depth |
: |
6.2mm |
Dimensions |
: |
80 x 6.2 x 94mm |
Minimum Operating Temperature |
: |
-25°C |
Maximum Operating Temperature |
: |
+60°C |
Manufacturer Part No. |
: |
2900355 |
Operating Temperature Range |
: |
-25 → +60°C |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST500-D DC12 |
Maximum Control Voltage |
: |
12 Vdc |
Maximum Load Current |
: |
3 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
26.4 Vdc |
Minimum Control Voltage |
: |
10.8 V |
Control Voltage Range |
: |
9.6 - 13.2 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
3 - 26.4V |
Minimum Load Voltage |
: |
3 Vdc |
Terminal Type |
: |
Push In |
Input Current |
: |
8mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
0.1 mA |
Length |
: |
88mm |
Output Device |
: |
MOSFET |
Depth |
: |
87.1mm |
Rise Time |
: |
6ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
6 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST500-D DC12 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Phoenix Contact |
MFR # |
: |
2900374 |
Mounting Type |
: |
DIN Rail |
Contact Configuration |
: |
SPST |
Terminal Type |
: |
Push In |
Input Current |
: |
3.5mA |
Height |
: |
94mm |
Series |
: |
PLC-OPT-230UC |
Length |
: |
80mm |
Depth |
: |
6.2mm |
Dimensions |
: |
80 x 6.2 x 94mm |
Minimum Operating Temperature |
: |
-25°C |
Maximum Operating Temperature |
: |
+60°C |
Manufacturer Part No. |
: |
2900374 |
Operating Temperature Range |
: |
-25 → +60°C |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST700-D DC12 |
Maximum Control Voltage |
: |
12 Vdc |
Maximum Load Current |
: |
3 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
26.4 Vdc |
Minimum Control Voltage |
: |
10.8 V |
Control Voltage Range |
: |
9.6 - 13.2 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
3 - 26.4V |
Minimum Load Voltage |
: |
3 Vdc |
Terminal Type |
: |
Screw |
Input Current |
: |
8mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
0.1 mA |
Length |
: |
88mm |
Output Device |
: |
Photovoltage Coupler |
Depth |
: |
87.1mm |
Rise Time |
: |
6ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
6 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST700-D DC12 |
Operating Temperature Range |
: |
-30 → 55°C |
|
Brand |
: |
Omron |
MFR # |
: |
G3RV-ST500-A AC230 |
Maximum Control Voltage |
: |
230 V ac |
Maximum Load Current |
: |
2 A |
Mounting Type |
: |
DIN Rail |
Maximum Load Voltage |
: |
264 V ac |
Minimum Control Voltage |
: |
207 V |
Control Voltage Range |
: |
184 - 253 V |
Switching Type |
: |
High-Speed |
Contact Configuration |
: |
SPDT |
Load Voltage Range |
: |
75 - 264V |
Minimum Load Voltage |
: |
75 V ac |
Terminal Type |
: |
Push In |
Input Current |
: |
7.5mA |
Height |
: |
90mm |
Series |
: |
G3RV-ST |
Minimum Load Current |
: |
100 mA |
Length |
: |
88mm |
Output Device |
: |
Triac |
Depth |
: |
87.1mm |
Rise Time |
: |
11ms |
Width |
: |
6.2mm |
Standards Met |
: |
CSA C22.2 No.14, EN 62314, IEC 60529, UL |
Off State Leakage Current |
: |
5 mA |
Package Style |
: |
Carton Box |
Dimensions |
: |
88 x 90 x 6.2mm |
Minimum Operating Temperature |
: |
-30°C |
Range |
: |
G3RV |
Special Features |
: |
60% Space Saving, Easy Maintenance |
Maximum Operating Temperature |
: |
+55°C |
Maximum Turn On Time |
: |
11 ms |
Isolation Voltage |
: |
2500V |
Manufacturer Part No. |
: |
G3RV-ST500-A AC230 |
Operating Temperature Range |
: |
-30 → 55°C |
|